Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Int J Mol Sci ; 24(4)2023 Feb 09.
Article in English | MEDLINE | ID: covidwho-2231230

ABSTRACT

As new SARS-CoV-2 variants emerge, there is an urgent need to increase the efficiency and availability of viral genome sequencing, notably to detect the lineage in samples with a low viral load. SARS-CoV-2 genome next-generation sequencing (NGS) was performed retrospectively in a single center on 175 positive samples from individuals. An automated workflow used the Ion AmpliSeq SARS-CoV-2 Insight Research Assay on the Genexus Sequencer. All samples were collected in the metropolitan area of the city of Nice (France) over a period of 32 weeks (from 19 July 2021 to 11 February 2022). In total, 76% of cases were identified with a low viral load (Ct ≥ 32, and ≤200 copies/µL). The NGS analysis was successful in 91% of cases, among which 57% of cases harbored the Delta variant, and 34% the Omicron BA.1.1 variant. Only 9% of cases had unreadable sequences. There was no significant difference in the viral load in patients infected with the Omicron variant compared to the Delta variant (Ct values, p = 0.0507; copy number, p = 0.252). We show that the NGS analysis of the SARS-CoV-2 genome provides reliable detection of the Delta and Omicron SARS-CoV-2 variants in low viral load samples.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Retrospective Studies , Viral Load , High-Throughput Nucleotide Sequencing
2.
Frontiers in medicine ; 8, 2021.
Article in English | EuropePMC | ID: covidwho-1651966

ABSTRACT

Introduction: Aside from the reverse transcription-PCR tests for the diagnosis of the COVID-19 in routine clinical care and population-scale screening, there is an urgent need to increase the number and the efficiency for full viral genome sequencing to detect the variants of SARS-CoV-2. SARS-CoV-2 variants assessment should be easily, rapidly, and routinely available in any academic hospital. Materials and Methods: SARS-CoV-2 full genome sequencing was performed retrospectively in a single laboratory (LPCE, Louis Pasteur Hospital, Nice, France) in 103 SARS-CoV-2 positive individuals. An automated workflow used the Ion Ampliseq SARS-CoV-2 panel on the Genexus Sequencer. The analyses were made from nasopharyngeal swab (NSP) (n = 64) and/or saliva (n = 39) samples. All samples were collected in the metropolitan area of the Nice city (France) from September 2020 to March 2021. Results: The mean turnaround time between RNA extraction and result reports was 30 h for each run of 15 samples. A strong correlation was noted for the results obtained between NSP and saliva paired samples, regardless of low viral load and high (>28) Ct values. After repeated sequencing runs, complete failure of obtaining a valid sequencing result was observed in 4% of samples. Besides the European strain (B.1.160), various variants were identified, including one variant of concern (B.1.1.7), and different variants under monitoring. Discussion: Our data highlight the current feasibility of developing the SARS-CoV-2 next-generation sequencing approach in a single hospital center. Moreover, these data showed that using the Ion Ampliseq SARS-CoV-2 Assay, the SARS-CoV-2 genome sequencing is rapid and efficient not only in NSP but also in saliva samples with a low viral load. The advantages and limitations of this setup are discussed.

3.
EBioMedicine ; 73: 103679, 2021 Nov.
Article in English | MEDLINE | ID: covidwho-1595805

ABSTRACT

BACKGROUND: The immunogenicity of a two-dose mRNA COVID-19 vaccine regimen is low in kidney transplant (KT) recipients. Here, we provide a thorough assessment of the immunogenicity of a three-dose COVID-19 vaccine regimen in this population. METHODS: We performed a prospective longitudinal study in sixty-one KT recipients given three doses of the BNT162b2 COVID-19 vaccine. We performed semi-structured pharmacovigilance interviews and monitored donor-specific antibodies and kidney function. We compared levels of anti-spike IgG, pseudo-neutralization activity against vaccine homologous and heterologous variants, frequency of spike-specific interferon (IFN)-γ-secreting cells, and antigen-induced cytokine production 28 days after the second and third doses. FINDINGS: Reactions to vaccine were mild. One patient developed donor-specific anti-HLA antibodies after the second dose which could be explained by non-adherence to immunosuppressive therapy. Spike-specific IgG seroconversion raised from 44·3% (n=27) after the second dose to 62·3% (n=38) after the third dose (p<0·05). The mean level of spike-specific IgG increased from 1620 (SD, 3460) to 8772 (SD, 16733) AU/ml (p<0·0001). Serum neutralizing activity increased after the third dose for all variants of concern tested including the Delta variant (p<0·0001). The frequency of spike-specific IFN-γ-secreting cells increased from 19·9 (SD, 56·0) to 64·0 (SD, 76·8) cells/million PBMCs after the third dose (p<0·0001). A significant increase in IFN-γ responses was also observed in patients who remained seronegative after three doses (p<0·0001). INTERPRETATION: A third dose of the BNT162b2 vaccine increases both cross-variant neutralizing antibody and cellular responses in KT recipients with an acceptable tolerability profile. FUNDING: Nice University Hospital, University Cote d'Azur.


Subject(s)
Antibodies, Neutralizing/immunology , BNT162 Vaccine/immunology , COVID-19/immunology , Kidney Transplantation , Aged , Antibodies, Neutralizing/blood , Autoantibodies/blood , BNT162 Vaccine/administration & dosage , BNT162 Vaccine/adverse effects , COVID-19/prevention & control , COVID-19/virology , Female , Graft Rejection/prevention & control , HLA Antigens/immunology , Humans , Immunoglobulin G/blood , Immunoglobulin G/immunology , Immunosuppressive Agents/therapeutic use , Interferon-gamma/metabolism , Leukocytes, Mononuclear/cytology , Leukocytes, Mononuclear/metabolism , Longitudinal Studies , Male , Middle Aged , Risk Factors , SARS-CoV-2/immunology , SARS-CoV-2/isolation & purification , SARS-CoV-2/metabolism , Spike Glycoprotein, Coronavirus/immunology
4.
Microbiol Spectr ; 9(3): e0099621, 2021 12 22.
Article in English | MEDLINE | ID: covidwho-1594122

ABSTRACT

Due to increased demand for testing, as well as restricted supply chain resources, testing for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection continues to face many hurdles. Pooling several samples has been proposed as an alternative approach to address these issues. We investigated the feasibility of pooling nasopharyngeal swab (NPS) or saliva samples for SARS-CoV-2 testing with a commercial assay (Idylla SARS-CoV-2 test; Biocartis). We evaluated the 10-pool and 20-pool approaches for 149 subjects, with 30 positive samples and 119 negative samples. The 10-pool approach had sensitivity of 78.95% (95% confidence interval [CI], 54.43% to 93.95%) and specificity of 100% (95% CI, 71.51% to 100%), whereas the 20-pool approach had sensitivity of 55.56% (95% CI, 21.20% to 86.30%) and specificity of 100% (95% CI, 25% to 100%). No significant difference was observed between the results obtained with pooled NPS and saliva samples. Given the rapidity, full automation, and practical advantages of the Idylla SARS-CoV-2 assay, pooling of 10 samples has the potential to significantly increase testing capacity for both NPS and saliva samples, with good sensitivity. IMPORTANCE To control outbreaks of coronavirus disease 2019 (COVID-19) and to avoid reagent shortages, testing strategies must be adapted and maintained for the foreseeable future. We analyzed the feasibility of pooling NPS and saliva samples for SARS-CoV-2 testing with the Idylla SARS-CoV-2 test, and we found that sensitivity was dependent on the pool size. The SARS-CoV-2 testing capacity with both NPS and saliva samples could be significantly expanded by pooling 10 samples; however, pooling 20 samples resulted in lower sensitivity.


Subject(s)
COVID-19 Testing/methods , COVID-19/diagnosis , Nasopharynx/virology , SARS-CoV-2/isolation & purification , Saliva/virology , Specimen Handling/methods , Adult , Diagnostic Tests, Routine , Female , Humans , Male , Middle Aged , Retrospective Studies
5.
ERJ Open Res ; 7(4)2021 Oct.
Article in English | MEDLINE | ID: covidwho-1562071

ABSTRACT

BACKGROUND: The current diagnostic standard for coronavirus disease 2019 (COVID-19) is reverse transcriptase-polymerase chain reaction (RT-PCR) testing with nasopharyngeal (NP) swabs. The invasiveness and need for trained personnel make the NP technique unsuited for repeated community-based mass screening. We developed a technique to collect saliva in a simple and easy way with the sponges that are usually used for tamponade of epistaxis. This study was carried out to validate the clinical performance of oral sponge (OS) sampling for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) testing. METHODS: Over a period of 22 weeks, we collected prospectively 409 paired NP and OS samples from consecutive subjects presenting to a public community-based free screening centre. Subjects were referred by their attending physician because of recent COVID-19 symptoms (n = 147) or by the contact tracing staff of the French public health insurance because they were considered as close contacts of a laboratory-confirmed COVID-19 case (n = 262). RESULTS: In symptomatic subjects, RT-PCR SARS-CoV-2 testing with OS showed a 96.5% (95% CI: 89.6-94.8) concordance with NP testing, and a 93.2% (95% CI: 89.1-97.3) sensitivity when using the IdyllaTM platform and a sensitivity of 76.3% (95% CI: 69.4-83.2) on the Synlab Barla laboratory platform. In close contacts the NP-OS concordance (93.8%, 95% CI: 90.9-96.7) and OS sensitivity (71.9%, 95% CI: 66.5-77.3) were slightly lower. CONCLUSION: These results strongly suggest that OS testing is a straightforward, low-cost and high-throughput sampling method that can be used for frequent RT-PCR testing of COVID-19 patients and mass screening of populations.

6.
Ann Transl Med ; 9(11): 921, 2021 Jun.
Article in English | MEDLINE | ID: covidwho-1278843

ABSTRACT

BACKGROUND: Management of large numbers of reverse transcriptase-polymerase chain reactions (RT-PCR) for diagnosis of coronavirus 2019 disease (COVID-19) requires robust infrastructures, located in dedicated premises with a high standard of biosafety procedures, and well-trained personnel. The handling of a "run-of-river sample" to obtain rapid reporting of results is challenging. METHODS: We studied the clinical performance of the Idylla™ SARS-CoV-2 Test (index test) on a platform capable of fully automated nucleic acid testing including extraction, amplification, and detection in a single-use cartridge to establish the diagnosis of COVID-19. The study was conducted on a prospective cohort of 112 volunteers with recent symptoms and an unknown SARS-CoV-2 status who came to free screening centers of the Nice metropolitan area. All subjects underwent bilateral nasopharyngeal sampling. One sample was processed using the index test, the other using the standard of care RT-PCR. Samples were treated blind. RESULTS: Most of the participants (70%) were sampled within 4 days of symptom onset. Forty-five (40.2%) were positive for COVID-19. No clinical symptoms were distinguished between SARS-CoV-2 RT-PCR positive and negative subjects except anosmia and dysgeusia. Positive and negative agreement between the index and the standard of care test was 100%. CONCLUSIONS: The Idylla™ SARS-CoV-2 Test is very sensitive, specific, rapid and easy to use in a near-patient RT-PCR approach to distinguish between symptomatic SARS-CoV-2 positive and negative patients in selected settings.

7.
Biopreserv Biobank ; 18(6): 517-524, 2020 Dec.
Article in English | MEDLINE | ID: covidwho-1125143

ABSTRACT

In only a few months after its inception, the COVID-19 pandemic lead to the death of hundreds of thousands of patients and to the infection of millions of people on most continents, mostly in the United States and in Europe. During this crisis, it was demonstrated that a better understanding of the pathogenicity, virulence, and contagiousness of SARS-CoV-2, all of which were initially underestimated, was urgently needed. The development of diagnostic tests to identify SARS-CoV-2 or to detect anti-SARS-CoV2 antibodies in blood, of vaccines, and of preventive and curative treatments has been relying on intense activity of scientists in academia and industry. It is noteworthy that these scientists depend on the use of high-quality biological samples taken from positive COVID-19 patients in a manner that preserves their integrity. Given this unique and emergent situation, it was necessary to urgently establish biological collections clinically annotated for immediate development of clinical and translational research projects focusing on COVID-19 biological aspects. It is in this very specific context that biobanks must rapidly adapt their infrastructure and/or operational capacity to fulfill new critical needs. We report the establishment of a biobank dedicated to the collection of blood-derived products (plasma, serum, and leukocytes) from COVID-19 patients hospitalized in the Nice Pasteur Hospital (Nice, France).


Subject(s)
Biological Specimen Banks , COVID-19/blood , COVID-19/epidemiology , SARS-CoV-2/metabolism , Translational Research, Biomedical , Female , France , Humans , Male
SELECTION OF CITATIONS
SEARCH DETAIL